CONTROLLED PEM TESTING / SINGLE CHANNEL

Single-Channel PEM Electrolyzer Test Platform

Control the test. Understand the electrolysis response.

Specify programmable electrical input, water management, temperature, back pressure and data acquisition around the device under test. Build a repeatable research programme with a defined measurement chain.

Application-led selection
Defined equipment scope
single channel pem electrolyzer test platform.webp
Reference configuration shown. Supplied equipment and appearance depend on the approved specification.

0–60 A

Reference current range

0–15 V

Power-supply range

RT–80°C

Reference temperature range

PURPOSE & VALUE

PEM Electrolyzer Test Platform Specifications

Control the test. Understand the electrolysis response.

The platform is designed around controlled PEM electrolysis experiments, including polarisation, durability and operating-condition studies. The reference configuration combines programmable DC power, a water circuit, controls and data recording. Confirm the sample interface and included measurement channels before specifying the final system.

01

Coordinate the experimental variables

Define current or voltage programmes alongside water flow, temperature and back pressure. Record stabilisation conditions so results can be compared across test runs.

02

Keep measurement scope explicit

Voltage inspection, power-supply output and optional flow measurement are separate functions. Match each required range and accuracy to the corresponding instrument channel.

03

Expand only where the experiment needs it

Higher-pressure operation, gas-composition monitoring and a dedicated fixture are listed as options. Include them explicitly when requesting a configuration.

PROCESS & INTEGRATION

Understand the equipment pathway.

01
Install DUT
02
Set water & thermal conditions
03
Apply electrical programme
04
Record synchronised data
05
Review results

TECHNICAL DETAILS

Reference technical specifications.

Reference data for configuration review. The accepted quotation and approved technical specification define the supplied equipment.

Subsystem Parameter Specification
Main Unit
Display Panel
Touchscreen
Alarm Component
Buzzer
Communication
USB · RJ45 Ethernet
Dimensions
500 × 400 × 540 mm
Hydrogen System
Back Pressure
0–0.4 MPa
Higher-Pressure Configuration
3 MPa Optional
Hydrogen Flow Measurement
Optional
Back-Pressure Accuracy
0.25% FS
Power
Voltage Inspection Range
0–3 V
Voltage Range
0–15 V
Voltage Scanning Accuracy
±0.2%
Current Range
0–60 A
CC Current Accuracy
≤1% + 30 mA
Water
Medium
Deionized Water
Adjustable Water Flow
0.15–600 mL/min
Water Refill
Automatic
Conductivity
≤1.4 μS/cm
Temperature
Adjustment
Room Temp–80°C
Control Accuracy
≤±0.5°C
Measurement Accuracy
≤±0.5°C
Resolution
0.01°C
Data
Voltage · Current · Temperature · Pressure · Flow · Conductivity
Tests
Polarization Curve · Durability · Voltage Monitoring
Safety
Hydrogen Leak Detection · High-Pressure Alarm · Emergency Stop · Interlock Shutdown
Structure
Modular Desktop Layout · 316L Stainless-Steel Piping
Optional
H₂-in-O₂ Monitoring · O₂-in-H₂ Monitoring · Oxygen Flow Monitoring · Dedicated Test Fixture
Power Supply
Programmable DC · CC/CV · PLC Control

Configuration note. Standard reference back pressure: 0–0.4 MPa. The 3 MPa configuration, hydrogen flow measurement, gas-composition monitoring and dedicated fixture are optional. Voltage inspection and power output are different channels.

SIDE-BY-SIDE SELECTION

Basic rack or research platform?

Feature Simple Test Rack Single-Channel Test Platform
Typical Use
Teaching · Basic R&D
Research · Advanced R&D
Current
0–30 A
0–60 A
Voltage
0–15 V
0–15 V
Water Flow
300 mL/min Reference
0.15–600 mL/min Adjustable
Water Refill
Manual One-Button
Automatic
Temperature
60°C Reference
80°C Reference
Back Pressure
Not Standard
0–0.4 MPa · 3 MPa Optional
Communication
USB
USB · RJ45 Ethernet
Control
Basic / Manual
Touchscreen · PLC
Gas Analysis
Not Standard
Optional
Safety
Basic Electrical Protection
Hydrogen Leak · Pressure Alarm · E-Stop · Interlock

Compare the functions required by your test programme. Optional equipment must be named in the quotation; published limits are not a substitute for an approved experimental envelope.

APPLICATIONS

Where this configuration fits.

01

Polarisation studies

Electrical response under controlled and documented test conditions.

02

Durability programmes

Time-series measurements with a defined duty cycle and data record.

03

Operating-condition research

Evaluate the selected variables within the approved test envelope.

BEFORE YOU REQUEST A QUOTE

Prepare a useful equipment brief.

01 / Device under test

Geometry, active area, terminals, ports and fixture requirements

02 / Test programme

Current/voltage range, duty, stabilisation and duration

03 / Measurements

Channels, accuracy, sampling rate and calibration evidence

04 / Options

Higher pressure, gas analysis, flow sensors and data interfaces

BUYER QUESTIONS

Questions before specification.

No. The reference back-pressure range is 0–0.4 MPa. A 3 MPa configuration is optional and requires a separate specification.

The source lists a dedicated fixture as an option. Confirm fixture geometry, materials and compatibility with the device under test.

No fixed cell geometry follows from the channel count. Supply the device dimensions and interfaces for a compatibility review.

The reference platform extends current, water adjustment, temperature, pressure and control capability. Use the comparison below to decide which functions your experiment actually needs.

NEXT STEP / CONFIGURATION REVIEW

Tell us what the equipment needs to do.

Send your application, destination country and technical requirements. Include the delivery target and any drawings or procurement specification so the proposed scope can be reviewed against your project.

Please name the product family in your enquiry. Final technical values, documentation and delivery terms belong in the approved quotation.

Your enquiry checklist

  • Device under test: Geometry, active area, terminals, ports and fixture requirements
  • Test programme: Current/voltage range, duty, stabilisation and duration
  • Measurements: Channels, accuracy, sampling rate and calibration evidence
  • Options: Higher pressure, gas analysis, flow sensors and data interfaces

SUBMIT YOUR REQUEST