Home / Products

PEM Electrolyzer Product Range

PEM Electrolyzer Systems & Stacks for B2B Hydrogen Projects

Compare complete PEM electrolyzer systems and stack platforms by hydrogen output, integration responsibility and application. Final specifications are confirmed against your operating conditions.

pem electrolyser c series 33.jpg

Choose the Right Product Scope

Do you need a complete system or a PEM stack?

The correct starting point depends on your in-house integration capability, project schedule and responsibility for balance-of-plant equipment.

Complete system

For end users, project developers and facilities

  • Integrated system configuration around the application
  • Defined utilities, controls and equipment boundary
  • Documentation and acceptance scope for the complete unit
  • Suitable when internal system integration is limited

PEM stack

For OEMs, integrators and equipment manufacturers

  • Stack platform selected by required hydrogen output
  • Customer integrates power, water, cooling and controls
  • Interface and operating envelope require engineering review
  • Suitable for experienced hydrogen-system developers

Complete PEM Systems

Compare published system capacity options

Use capacity as the first screening step. Purity, pressure, energy use, system boundary and compliance must be confirmed in the model-specific proposal.

Compact system
pem electrolyser%e2%80%93s series 11.jpg

0.6 Nm³/h

PEM Electrolyzer System

Compact on-site hydrogen platform for laboratory, research and lower-flow industrial requirements.

  • Laboratory and R&D
  • Fuel-cell testing
  • Specialty process supply

Published model

Compact industrial
pem electrolyser h series 22.jpg

1 Nm³/h

PEM Electrolyzer System

For continuous on-site hydrogen requirements where compact footprint and system integration matter.

  • On-site gas supply
  • Industrial R&D
  • Small process loads
Published model
Industrial system
pem electrolyser h series 22.jpg

10 Nm³/h

PEM Electrolyzer System

Project-based industrial platform for process hydrogen and integration with variable power sources.

  • Industrial processes
  • Renewable integration
  • Distributed hydrogen
Published model
High-capacity system
pem electrolyser c series 33.jpg

50 Nm³/h

PEM Electrolyzer System

For higher-throughput industrial hydrogen projects requiring a clearly defined equipment and utility scope.

  • Industrial hydrogen
  • Energy projects
  • Chemical processes

Published model

Large industrial system
pem electrolyser m series 44.jpg

200 Nm³/h

PEM Electrolyzer System

Large project configuration requiring detailed site, power, water, safety and balance-of-plant review.

  • Large industrial demand
  • Hydrogen infrastructure
  • Project integration
Published model
Custom project
pem electrolyser l series 55.jpg

Custom requirement

Application-Specific Configuration

For projects not matched by a standard published model or requiring special controls, interfaces or packaging.

  • OEM configuration
  • Special interfaces
  • Project-specific scope
Engineering review

Specification notice: capacities above reflect currently published product pages. Final model, hydrogen purity, pressure, energy consumption, dimensions, compliance and scope of supply require written engineering confirmation.

PEM Stack Range

Stack platforms for OEM and system integration

A stack is not a complete hydrogen plant. Confirm electrical input, cooling, water loop, gas handling, pressure control, sensors and safety logic before selection.

pem electrolyser stack 66.jpg

Published capacity

7000 mL/min

Product type

Compact PEM stack

Typical selection stage

Laboratory / small OEM equipment

1 Nm³/h

PEM stack
Compact system integration

2 Nm³/h

PEM stack
OEM / distributed hydrogen

3 Nm³/h

PEM stack
OEM / distributed hydrogen

4 Nm³/h

PEM stack
OEM / process integration

5 Nm³/h

PEM stack
OEM / process integration

10 Nm³/h

Industrial PEM stack
Industrial system integration

60 Nm³/h

High-capacity PEM stack
Large OEM / project integration

200 Nm³/h

Large PEM stack
Large industrial project review

Application Fit

Select by process requirements—not capacity alone

The same hydrogen output can require a different product scope depending on purity, redundancy, control and operating profile.

RE

Renewable Energy

Review variable-load operation, controls, storage boundary and grid or off-grid power conditions.

IN

Industrial Process

Define uptime, process consumption, delivery pressure and permitted maintenance windows.

SC

Semiconductor

Confirm impurity limits, drying, purification, monitoring and redundancy requirements.

RD

Laboratory & R&D

Match flow control, footprint, noise, ventilation and connection requirements to the facility.

Selection Checklist

Information required for reliable model selection

01 · PROCESS

Hydrogen requirement

  • Rated and peak H₂ output
  • Purity and dew point
  • Outlet pressure
  • Daily operating profile

02 · SITE

Utilities and environment

  • Power supply and quality
  • Water quality and availability
  • Cooling conditions
  • Indoor/outdoor environment

03 · PROJECT

Scope and acceptance

  • System or stack boundary
  • Controls and communication
  • Required certificates
  • FAT, warranty and delivery

Product FAQ

Questions before choosing a PEM electrolyzer

A product-page number is only a starting point. The final configuration depends on the complete operating requirement.

What is the difference between a PEM system and a PEM stack?

The stack is the electrochemical core. A complete system may additionally include power conversion, water circulation and treatment, cooling, gas separation or purification, controls, sensors and safety equipment. Confirm the exact boundary in writing.

No. Flow is the first filter, but purity, pressure, operating profile, ambient conditions, power supply, water quality, redundancy and certification also affect selection.

The page lists currently published model capacities. Production status, lead time, final configuration and availability must be confirmed in the quotation.

Compare rated output, purity measurement point, outlet pressure, specific energy consumption boundary, turndown, utilities, safety scope, FAT criteria, warranty and after-sales responsibility under the same conditions.

Customization feasibility can be reviewed for output, interfaces, controls, packaging and documentation. The engineering team must assess the application, order volume and qualification scope.

Model Selection Request

Tell us what the hydrogen system must do

Send the operating requirement first. The engineering sales team can then review whether a complete system, a stack or a custom configuration is the better fit.

Useful attachments

  • Technical specification or RFQ
  • Hydrogen consumption profile
  • Site utility information
  • Required standards and schedule

SUBMIT YOUR REQUEST